Variants of OPC-UA Technology and its use in the interconnection of Industrial Controllers with different communication protocols.

Authors

DOI:

https://doi.org/10.37431/conectividad.v3i2.44

Keywords:

OPC-UA technology, Intercommunication, Communication protocol, Industrial controller

Abstract

In the industrial area there is a choice of controller technologies with different characteristics, which makes this form of intercommunication and interoperability difficult, due to this OPCUA technology has been proposed as an alternative that allows intercommunication between controllers from different manufacturers. The objective of this work is to analyze the use of this technology for the intercommunication of industrial controllers with different communication protocols through the analysis of case studies with different characteristics regarding security, encryption and digital signature. The results showed that the use of the OPC-UA communication system reduced the configuration complexities as it supported open systems, tolerated firewalls and configuration. Allowing the immediate validation of variables from the SCADA system to the industrial controllers without prior configuration. With this it can be concluded that the OPC-UA communication can successfully replace the traditional OPC system.

References

Adlok, N., & Nikam, A. (2017). Automatic testing of medium voltage drive using OPC server interface. 2017 International Conference on Smart grids, Power and Advanced Control Engineering (ICSPACE), 65-68. https://doi.org/10.1109/ICSPACE.2017.8343407

Almeida, C. (s. f.). Unified Architecture. OPC Foundation. Recuperado 30 de junio de 2022, de https://opcfoundation.org/about/opc-technologies/opc-ua/

Drahoš, P., Kučera, E., Haffner, O., & Klimo, I. (2018). Trends in industrial communication and OPC UA. 2018 Cybernetics & Informatics (K&I), 1-5. https://doi.org/10.1109/CYBERI.2018.8337560

Eckhardt, A., Müller, S., & Leurs, L. (2018). An Evaluation of the Applicability of OPC UA Publish Subscribe on Factory Automation use Cases. 2018 IEEE 23rd International Conference on Emerging Technologies and Factory Automation (ETFA), 1, 1071-1074. https://doi.org/10.1109/ETFA.2018.8502445

Eymüller, C., Hanke, J., Hoffmann, A., Kugelmann, M., & Reif, W. (2020). Real-time capable OPC-UA Programs over TSN for distributed industrial control. 2020 25th IEEE International Conference on Emerging Technologies and Factory Automation (ETFA), 1, 278-285. https://doi.org/10.1109/ETFA46521.2020.9212171

Germany, B. A. G. & C. K., Hülshorstweg 20, 33415 Verl. (s. f.). Beckhoff New Automation Technology. Beckhoff Automation. Recuperado 30 de junio de 2022, de https://www.beckhoff.com/es-es/

Han, D., Gong, Y., & Xu, D. (2022). Research on Key Technologies of OPC UA Standard and Test. 2022 IEEE Asia-Pacific Conference on Image Processing, Electronics and Computers (IPEC), 95-98. https://doi.org/10.1109/IPEC54454.2022.9777611

Krylova, E. L., Nemudruk, M. L., Shchurov, D. A., Novozhilov, I. M., & Fedorov, M. S. (2021). The Use of OPC UA Technology in the Study of Models of Control Objects. 2021 IV International Conference on Control in Technical Systems (CTS), 171-173. https://doi.org/10.1109/CTS53513.2021.9562917

Lai, Y. H., Huang, Y.-H., Lai, C. F., Chen, S. Y., & Chang, Y.-C. (2020). Dynamic Adjustment Mechanism based on OPC-UA Architecture for IIoT Applications. 2020 Indo - Taiwan 2nd International Conference on Computing, Analytics and Networks (Indo- Taiwan ICAN), 335-338. https://doi.org/10.1109/Indo-TaiwanICAN48429.2020.9181337

Marksteiner, S. (2018). Reasoning on Adopting OPC UA for an IoT-Enhanced Smart Energy System from a Security Perspective. 2018 IEEE 20th Conference on Business Informatics (CBI), 02, 140-143. https://doi.org/10.1109/CBI.2018.10060

Muennoi, A., & Hormdee, D. (2016). 3D Web-based HMI with WebGL Rendering Performance. MATEC Web of Conferences, 77, 09003.

https://doi.org/10.1051/matecconf/20167709003

Okuda, M., Mizuya, T., & Nagao, T. (2017). Development of IoT testbed using OPC UA and database on cloud. 2017 56th Annual Conference of the Society of Instrument and Control Engineers of Japan (SICE), 607-610. https://doi.org/10.23919/SICE.2017.8105726

OPC UA_test. (s. f.). Recuperado 3 de julio de 2022, de https://page.advantech.com/opc-ua- test

Ren, H., Liu, Y., & Wang, H. (2019). Research on Communication Method of OPC UA Client Based on ARM. 2019 IEEE/ACIS 18th International Conference on Computer and Information Science (ICIS), 52-56. https://doi.org/10.1109/ICIS46139.2019.8940214 Rivera-Velazquez, F., Salazar-Valle, E., & Martínez-Águilar, G. M. (2021). OPC UA server on Raspberry Pi and Arduino for didactic use. 2021 10th International Conference On Software Process Improvement (CIMPS), 115-124. https://doi.org/10.1109/CIMPS54606.2021.9652694

Schwarz, M. H., & Börcsök, J. (2013). A survey on OPC and OPC-UA: About the standard, developments and investigations. 2013 XXIV International Conference on Information, Communication and Automation Technologies (ICAT), 1-6. https://doi.org/10.1109/ICAT.2013.6684065

Yuan, H., Hao, H., & Zhang, M. (2021). Overview of OPC UA TSN. 2021 IEEE 5th Information Technology,Networking,Electronic and Automation Control Conference (ITNEC), 5, 715-718. https://doi.org/10.1109/ITNEC52019.2021.9586911

Published

2022-07-12

How to Cite

Jácome, F., Andagoya, L. D., Valencia, R., Osorio, H., & Paredes, E. (2022). Variants of OPC-UA Technology and its use in the interconnection of Industrial Controllers with different communication protocols. CONECTIVIDAD, 3(2), 56–74. https://doi.org/10.37431/conectividad.v3i2.44

Issue

Section

Research Articles

Most read articles by the same author(s)